 NEW 200W Outdoor TWT Amplifier for Satellite Communications
Ku- Band
The T02UO-2G 200 Watt TWT Power Amplifier -- higher efficiency in an environmentally sealed compact package designed for outdoor operation
Ku-Band
note: photo is not necessarily representative of your desired configuration
Less Prime Power, More Efficient
Highly Compact
CPI's new environmentally sealed 200 W Ku-band hubmount TWTA is the most efficient amplifier in its class. Consuming only 650 W prime power to achieve 175 W at the flange, the Mini-Ku is at least 24% more efficient than any similar product.
Reliable
10% smaller and 25% lighter than any other 200 W TWTA.
Easy to Maintain
200W Outdoor TWT Amplif ier
Modular design and built-in fault diagnostic capability via remote monitor and control.
Global Applications
Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60C.
Digital Ready, Simple to Operate
Meets International Safety Standard EN-60215, Electromagnetic Compatibility 2004/108/EC and Harmonic Standard EN-61000-3-2 to satisfy worldwide requirements.
Worldwide Support
User-friendly microprocessor-controlled logic. Integrated Ethernet computer interface and forward power detection over CIF are now standard. A variety of optional configurations, including integral linearizers and BUCs, is available.
Backed by over three decades of satellite communications experience and CPI's worldwide 24-hour customer support network that includes sixteen regional factory service centers.
811 Hansen Way P.O. Box 51625, Palo Alto, CA 94303 tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail: satcommarketing@cpii.com www.cpii.com/satcom
Ku -B a n d
SPECIFICATIONS, T02UO-2G
Electrical
Frequency 13.75 to 14.50 GHz (output, wideband option 12.75 to 14.50 GHz) 950 MHz to 1700 MHz (input w/BUC option) 200 W min. (53.01 dBm) 175 W min. (52.43 dBm) 750 MHz (1750 MHz with wideband option) 35 dB min. at rated power output (68 dB min. with SSIPA option); 41 dB min. at small signal (70 dB min. with SSIPA option) 0.45 dB/24hr max. (at constant drive and temp.) 0.04 dB/MHz max. 1.0 dB pk-pk across any 80 MHz band; 3.5 dB pk-pk across the 750 MHz band 5.0 dB pk-pk across 1750 MHz (wideband option) 30 dB typ. (not available with low gain version) 1.3:1 max. 2.2:1 max. (1.3:1 max. with optional output circulator) 2.0:1 max. continuous operation; any value for operation without damage -120 dBc/Hz at 10 Hz -140 dBc/Hz at 100 Hz -145 dBc/Hz at 1 kHz -150 dBc/Hz at 10 kHz (Level -3 to +7 dBm) Relative Humidity Altitude
Electrical (continued)
Intermodulation -24 dBc max. with respect to the sum of both carriers at total output power 7 dB OBO (4 dB OBO with optional linearizer) 100-240 VAC 10% single phase, 47-63 Hz 650 W typ. 0.95 min.
OPTIONS: * Remote Control Panel * Redundant Subsystems * Integrated 1:1 switch control and drive * Integral Linearizer * Extended Frequency --12.75 - 14.50 GHz * Integral L-Band Block Upconverter (BUC --- option is available over 12.75 to 13.25 GHz OR 13.75 to 14.50 GHz frequency ranges only) * Attenuated Solid State IPA
Output Power TWT Flange Bandwidth Gain
Primary Power Power Consumption Power Factor
Environmental (Operating)
Ambient Temperature -40C to +60C operating, including solar loading; -40C to +71C non-operating 100% condensing 10,000 ft. with standard adiabatic derating of 2C/1000 ft., operating; 50,000 ft., non-operating 20 g pk, 11 mS, 1/2 sine 3 grms 65 dBA @ 3 ft. from amplifier
Gain Stability Small Signal Gain Slope Small Signal Gain Variation
Shock Vibration Acoustic Noise
RF Level Adjust Range Input VSWR Output VSWR Load VSWR MUXed External 10 MHz Reference Phase Noise Required (L-Band Input 950 - 1700 MHz) 1 BUC option only
Mechanical
Cooling L-Band Input Connection RF Input Connection RF Output Connection Forced air with integral blower Type N female (BUC option only) Type N female (standard) WR-75 waveguide flange, grooved with UNC 2B 6-32 threaded holes Type N female, 44 dB nom. 8.5 x 8.5 x 15.0 in. max. (216 x 216 x 381 mm) 24.25 lbs (11.0 kg) with no options; 25.41 lbs (11.5 kg) with BUC
RF Output Monitor Dimensions (W x H x D) Weight
Single Sideband Phase Noise -63 dBc at 100 Hz offset BUC option only -73 dBc at 1 kHz offset -83 dBc at 10 kHz offset -93 dBc at 100 kHz offset -103 dBc at 1 MHz offset -113 dBc at 10 MHz offset Residual AM -50 dBc below 10 kHz -20 [1.5 + log F(kHz)] dBc 10 kHz to 500 kHz 12 dB below IESS-308 continuous mask (3 dB below mask with BUC option) -60 dBc max. at 175 W flange output 2.0/dB max. for a single carrier up to 7 dB OBO (up to 4 dB OBO with linearizer option) -60 dBc max. at rated power <-130 dBW/4 kHz, below 12.7 GHz <-70 dBW/4 kHz, passband <-66 dBW/4 kHz, passband with linearizer
Note 1: External 10 MHz reference must be multiplexed with the RF input signal.
Phase Noise Spurious AM/PM Conversion Harmonic Output Noise Power Density (at maximum gain)
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 249, ISSUE 10 02/09 PDF


▲Up To Search▲   

 
Price & Availability of T02UO-2G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X